Home >
860FC
|
860FC - Handheld DSO/DMM with Data Logger and USB Port
|
| |
| |
|
Click on image for larger
picture
|
|
|
| |
60MHz Analog bandwidth |
| |
Up to 200Ms/S sampling rates (100Ms/S Dual channel) |
| |
High Resolution 3.8". 320 x 240 Pixel Color LCD |
| |
125Kb record length for each channel |
| |
Real Time Data logger |
| |
Built in 6000 count DMM for measuring DC and True RMS AC volts, Ohms and Current with optional Currrent Clamp |
| |
Horizontal Zoom function and advanced triggering |
| |
2.5Gs/S Equivilent Sampling rate |
| |
22 Automatic waveform measurements |
| |
Auto Scale sets up waveform to the optimum Horizontal and Vertical scale settings |
| |
Dual channel (A + B), (A - B), and (B - A) waveform math |
| |
FFT with Hannig, Hamming, Rectangular and Black-Harris weighting |
| |
Multi-Lingual language help support with a push of a button |
| |
High Speed USB 2.0 interface and USB Host port are standard features |
| |
Battery pack, Software, and USB cable are standard accessories |
|
|
| |
|
| Related Links |
|
|
|
| |
|
| Specification |
|
|
|
| No. of inputs |
2 |
| Analog Bandwidth |
60MHz |
| Rise Time |
< 5.83nS |
| Sensitivity |
5mV/Div to 100V/Div in (1-2-5 sequence) |
| Resolution |
8 Bits |
| Off set |
±5% from the center |
| Vertical accuracy |
±3% |
| Input Impedance |
1MW and ±20pF ±1.3pF |
| Max. Input Volts |
300VDC or AC Peak |
| Probe Attenuation |
x1 and x10 |
|
|
|
|
| Sweep rates |
5nS/Div to 50S/Div |
| Time base Accuracy |
±3% |
| Posistion Range |
Pre-Trigger: 20Div Max. Post-Trigger: 1000 Div. |
| Horizontal Modes: |
Main Sweep, XY |
| Delta Time Measurement accuracy |
± 3% |
|
|
|
|
| Acquisition modes |
Sample, Peak detect, Envelope, Average |
| Sampling |
Real Time and Equivilent |
| Sample Rate rates |
Up to 200Ms/s Single channel and 100Ms/S Dual Channel |
| Equivilent Sampling Rate |
Up to 2.5Gs/S |
| Sample Rate Accuracy |
±100ppm |
| Record Length |
125KB/Channel |
| Waveform Interpolation |
Dot, Linear, Sine and Pulse |
| Peak Detect |
10nS minimum |
| Averages |
2 to 256 |
|
|
|
|
| Sensitivity |
0.5Div (DC to 5MHz) |
| Advanced Trigger types |
Edge, Pulse width, Video |
| Coupling |
AC, DC HF- Reject, LF- Reject, Noise Reject |
| Mode |
Normal, Single, Roll and Auto |
| Trigger Level range |
±20Div. from the center of the screen |
| Trigger Level accuracy |
±0.4Div |
| Trigger Sources |
ChA and ChB |
| Trigger Level resolution |
500 Pixels |
|
|
|
|
| Video Trigger sensitivity |
0.7Div |
| Video Types |
NTSC, PAL and SECAM |
| Video Trigger sources |
ChA or ChB |
| Video Triggers |
Odd/Even frames, All frames, Line number (Lines 5 to 263 within a frame) |
|
|
|
|
| Type |
P-P, Max, Amplitude, Top, Base, Pos/Neg. overshoot, Preshoot, RMS, Mean, One cycle Mean, Freq, Period, ±Width, ±Dutycycle, Rise/Fall time, Delay and Phase shift |
|
|
|
|
| Dual Channel Math |
ChA + ChB, ChA - ChB, ChB - ChA, FFT |
| Cursors |
Voltage: Y1, Y2, ∆V Time: Y1, Y2, ∆T |
|
|
|
|
| Weighting |
Rectangular, Hamming, Hanning, Blackman-Harris |
| Amplitude display |
1dB, 2dB, 5dB, 10dB and 20dB per Division |
| Maximum Frequency |
1.25GHz |
|
|
|
|
| Memory |
10 Waveforms and settings maybe stored and recalled |
|
|
|
|
| Source |
DMM |
| Range |
10 divisions on the LCD |
| Record size |
256 data points |
| Time span |
Auto ranging from 150 Sec to 20 days |
| Measurement parameters |
Min., Max. or Avg. |
|
|
|
|
|
|
|
|
|
| Ranges |
600mV to 1000V |
| Accuracy |
±(0.3% +10d) |
| Best Resolution |
100µV |
| Input Impedance: |
10MW |
| Overload protection |
1000V DC or AC peak |
|
|
|
|
| Ranges |
6V to 600V |
| Accuracy |
±(0.75% +10d) 50Hz to 1KHz ±(2.0% +10d) 1KHz to 30KHz |
| Best Resolution |
1mV |
| Input Impedance |
10MW |
| Overload protection |
1000V DC or AC Peak |
|
|
|
|
| Ranges |
600W to 60MW |
| Accuracy |
±(0.5% +10d) |
| Best Resolution |
100mW |
| Overload Protection |
250VDC or AC peak |
|
|
|
|
| Ranges |
60nF to 300µF |
| Accuracy |
±(2.0% +10d) |
| Best Resolution |
1pF |
|
|
|
|
| Diode test |
Accuracy: ±2% |
| Continuity |
Buzzer will sound: <60W |
| dB measurements |
dBm reference values (in ohms) 2, 4, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, or 2000 |
| Analog bargraph |
60 segments |
| Current measurement with Optional current clamp |
600A |
|
|
|
|
| Dimensions (L x W x D) |
4.2" x 8.3" x 2.2" |
| Weight |
2.6lbs (1.18Kg) |
| Power |
9VDC @ 1A AC/DC wall adapter 7.2V NiMh rechargeable , 2800mAH battery pack |
| Standard accessories |
(2) x1 x10 Scope probes, Holster, USB cable and Software |
| Optional accessories |
600A clamp on current transducer and carrying bag |
|
|
|
|
|