  •    Specification
  • DC Volts
    Ranges 400mV, 4V, 40V, 400V, 1000V
    Best Resolution 100µV
    Accuracy ± (0.7% + 2d)
    Input Impedance 10MW
    Maximum Input Volts 250V, (400mV range), 1000V all other ranges
    AC Volts
    Ranges 400mV, 4V, 40V, 400V, 1000V
    Best Resoluton 100µV
    Accuracy ±(3.0% + 3d) 400mV range; ±(1.0% + 3d) 1000V range; ±(0.8% + 3d) all other ranges
    Input Impedance: 10MW
    Overload Protection 250V 400mV range ; 750Volts RMS all other ranges
    DC Current
    Ranges 400µA, 4000µA, 40mA, 400mA, 4A and 10A
    Best Resolution 100nA
    Accuracy ±(3.0% + 7d) 4A and 10A ranges ; ±(1.2% + 3d) all other ranges
    Overload Protection 500mA resettable fuse and 10A/250V fuse
    AC Current
    Ranges: 400µA, 4000µA, 40mA, 400mA, 4A and 10A
    Best Resolution 100nA
    Accuracy ±( 3% + 7d) 4A and 10A ranges; ±(1.5% + 5d) all other ranges
    Overload protection 500ma resettable fuse and 10/250 V fuse
    Resistance
    Ranges 400W, 4KW, 40KW, 400KW, 4MW, 40MW
    Best Resolution 0.1W
    Accuracy ±(2% + 2d) 40MO range; ±(1.2% + 2d) all other ranges
    Open circuit Voltage approx. 250mV
    Overload protection 250V Dc or rms
    Capacitance
    Ranges 4nF, 40nF, 400nF, 4µF, 40µF and 200µF
    Best Resolution 1pF
    Accuracy ±(3.0% + 3d)
    Overload Protection 250V DC or rms
    Frequency
    Ranges 9.999Hz, 99.99Hz, 999.9Hz, 9.999KHz, 99.99KHz amd 199.9KHz
    Best Resolution 0.001Hz
    Accuracy ±(2.0% + 5d) 10Hz and 200KHz range; ±(1.5% + 5d) all other ranges and unspecified > 200KHz
    Overload protection 250V DC or rms
    Sensitivity 0.6V to 3V rms
    Duty Cycle
    Range 0.1% to 99.9%
    Resolution 0.1%
    Accuracy ±3.0%
    Temperature (Ambient displayed on LCD)
    Range 0º to 40ºC ( 32ºF to 104ºF)
    Resolution 0.1º C or F
    Accuracy ± 2º C and ± 4º F
    Temperatue (with Themocouple)
    Range -20ºC to 1000ºC (-4ºF to 1832ºF)
    Resolution 0.1º C or F
    Accuracy ±(5% or 3ºC) -20ºC to 0ºC; ±(1.0% or 2ºC)0ºC to 400ºC; ±(2.0%) 400ºC to 1000ºC; ±(5% or 6ºF)-4ºF to 32ºF; ±(1% or 4ºF) 32ºF to 752ºF; ±2%, 752º to 1832ºF
    Overload Protection 500mA/250V resettable fuse
    Continuity Buzzer
    Open Circuit Voltage 0.5Volts
    Buzzer will sound at < 40W resistance
    Diode
    Open Circuit Voltage 1.5V DC
    Test Current 1mA DC
    Overload Protection 250V DC or rms
    Sound Level
    Range 40dB to 100dB
    Resolution 0.1dB
    Accuracy ±3.5% at 94dB and 1Khz Sinewave
    Frequency Range 100Hz to 8KHz
    Luminance
    Ranges 0 to 4,000 Lux (x1) and 0 to 40,000 Lux (x100)
    Resolutions 1 Lux (x1) and 10 Lux (10)
    Accuracy ±(5% +10d) at a color temperature of 2856K, calibrated to a standard incandescent lamp
    General Specifications
    Operating Temperture 0 to 40° C (32°F to 122°F) with an R.H. of < 70%
    Dimensions 7.7" (H) x 3.6" (W) x 2.2" (D)
    Weight 14.3 oz
    Standard Accessories Test Leads, Operator's manual and Batteries