|
|
     |
| |
|
|
Home >
Products
>
Multimeters
>
AC/DC Clamp-On
>
6300
|
| 6300 - 3 3/4 Digit 5 in one DMM with Luminance, Sound level and Relative Humidity
|
| |
| |
|
Click on image for larger
picture
|
|
|
| |
Five meters in one, Humidity, Luminance, Sound level, Temperature +DMM |
| |
Buzzer and flashing light warning when leads are connected to wrong input and Overload |
| |
Display Reads Humidty, and ambient temperature along with measurement value |
| |
3 3/4 Digit, 4,000 count with Backlit display |
| |
Relative mode and Data hold |
| |
Resettable fuses, no need to open meter to replace a blown fuse |
| |
Temperture measuement in Celsius and Fahrenheit |
| |
Measures Duty cycle, Frequency and Capacitance |
| |
MSRP: $82.00 |
|
|
| |
|
| Related Links |
|
|
|
| |
|
| Specification |
|
|
|
| Ranges |
400mV, 4V, 40V, 400V, 1000V |
| Best Resolution |
100µV |
| Accuracy |
± (0.7% + 2d) |
| Input Impedance |
10MW |
| Maximum Input Volts |
250V, (400mV range), 1000V all other ranges |
|
|
|
|
| Ranges |
400mV, 4V, 40V, 400V, 1000V |
| Best Resoluton |
100µV |
| Accuracy |
±(3.0% + 3d) 400mV range;
±(1.0% + 3d) 1000V range;
±(0.8% + 3d) all other ranges
|
| Input Impedance: |
10MW |
| Overload Protection |
250V 400mV range ; 750Volts RMS all other ranges |
|
|
|
|
| Ranges |
400µA, 4000µA, 40mA, 400mA, 4A and 10A |
| Best Resolution |
100nA |
| Accuracy |
±(3.0% + 7d) 4A and 10A ranges ; ±(1.2% + 3d) all other ranges |
| Overload Protection |
500mA resettable fuse and 10A/250V fuse |
|
|
|
|
| Ranges: |
400µA, 4000µA, 40mA, 400mA, 4A and 10A |
| Best Resolution |
100nA |
| Accuracy |
±( 3% + 7d) 4A and 10A ranges; ±(1.5% + 5d) all other ranges |
| Overload protection |
500ma resettable fuse and 10/250 V fuse |
|
|
|
|
| Ranges |
400W, 4KW, 40KW, 400KW, 4MW, 40MW
|
| Best Resolution |
0.1W |
| Accuracy |
±(2% + 2d) 40MO range; ±(1.2% + 2d) all other ranges |
| Open circuit Voltage |
approx. 250mV |
| Overload protection |
250V Dc or rms |
|
|
|
|
| Ranges |
4nF, 40nF, 400nF, 4µF, 40µF and 200µF |
| Best Resolution |
1pF |
| Accuracy |
±(3.0% + 3d) |
| Overload Protection |
250V DC or rms |
|
|
|
|
| Ranges |
9.999Hz, 99.99Hz, 999.9Hz, 9.999KHz, 99.99KHz amd 199.9KHz |
| Best Resolution |
0.001Hz |
| Accuracy |
±(2.0% + 5d) 10Hz and 200KHz range; ±(1.5% + 5d) all other ranges and unspecified > 200KHz |
| Overload protection |
250V DC or rms |
| Sensitivity |
0.6V to 3V rms |
|
|
|
|
| Range |
0.1% to 99.9% |
| Resolution |
0.1% |
| Accuracy |
±3.0% |
|
|
| Temperature (Ambient displayed on LCD) |
|
| Range |
0º to 40ºC ( 32ºF to 104ºF) |
| Resolution |
0.1º C or F |
| Accuracy |
± 2º C and ± 4º F |
|
|
| Temperatue (with Themocouple) |
|
| Range |
-20ºC to 1000ºC (-4ºF to 1832ºF) |
| Resolution |
0.1º C or F |
| Accuracy |
±(5% or 3ºC) -20ºC to 0ºC;
±(1.0% or 2ºC)0ºC to 400ºC;
±(2.0%) 400ºC to 1000ºC;
±(5% or 6ºF)-4ºF to 32ºF;
±(1% or 4ºF) 32ºF to 752ºF;
±2%, 752º to 1832ºF |
| Overload Protection |
500mA/250V resettable fuse |
|
|
|
|
| Open Circuit Voltage |
0.5Volts |
| Buzzer will sound at |
< 40W resistance |
|
|
|
|
| Open Circuit Voltage |
1.5V DC |
| Test Current |
1mA DC |
| Overload Protection |
250V DC or rms |
|
|
|
|
| Range |
40dB to 100dB |
| Resolution |
0.1dB |
| Accuracy |
±3.5% at 94dB and 1Khz Sinewave |
| Frequency Range |
100Hz to 8KHz |
|
|
|
|
| Ranges |
0 to 4,000 Lux (x1) and 0 to 40,000 Lux (x100) |
| Resolutions |
1 Lux (x1) and 10 Lux (10) |
| Accuracy |
±(5% +10d) at a color temperature of 2856K, calibrated to a standard incandescent lamp |
|
|
|
|
| Operating Temperture |
0 to 40° C (32°F to 122°F) with an R.H. of < 70% |
| Dimensions |
7.7" (H) x 3.6" (W) x 2.2" (D) |
| Weight |
14.3 oz |
| Standard Accessories |
Test Leads, Operator's manual and Batteries |
|
|
|
|
|