B4100 - Bench Top Programmable Digital Multimeter  
 
 
Click for larger picture

Click on image for larger picture

   
5-1/2 Digit multimeter with selectable count resolutions up to 200,000
True RMS and measures frequency
Selectable Count Resolutions: 2K, 20K, 200K
Auto-ranging
Trend plot display
RS-232 interface standard and optional GPIB interface
Min/Max/Avg, Relative error and comparison functions
May be used on line voltages from 85V to 250V without any internal changes
Software included
Seven setups may be stored and recalled in memory
MSRP: $536.00 ($669.00 with GPIB)
 
  •    Related Links
  •    Request Quotation    Request Demo
       Download Product Data Sheet    User Manual (2.0 MB)
       Multimeter Selection Guide    Programming Manual (332 KB)
       Download software (475KB)
     
  •    Specification
  • Display
    Slow Counts: 200,000
    Digits: 5 ½
    Medium Counts: 20,000
    Digits: 4 ½
    Fast Counts: 2,000
    Digits: 3 ½
    DC Voltage
    Ranges 2V, 20V, 200V, 1000V
    Best Resolutions 10µV (Slow), 100µV (Med), 1mV (Fast)
    Accuracy ±(0.05% + 3d)
    Input Impedance 10MW
    Overload Protection 1000V
    AC Volts
    Ranges 2V, 20V, 200V, 1000V
    Best Resolutions 100µV (Slow and Med), 1mV (Fast)
    Accuracy ±(0.5% + 5d) 45Hz to 450Hz
    Overload Protection 1000V
    Crest Factor 3:1
    DC Current
    Ranges 200µA, 200mA, 10A
    Best Resolutions 200µA: 1nA (Slow), 10nA (Med),100nA (Fast)
    200mA: 1µA (Slow), 10µ (Med), 100µA (Fast)
    10A: 100µA (Slow), 1mA (Med), 10mA (Fast)
    Accuracy ±(0.1% + 5d), Max burden: 200mV
    Overload Protection 0.5A/250V and 10A/250V fuse
    AC Current
    Best Resolutions 200µA: 10nA (Slow and Med), 100nA (Fast)
    200mA: 1µA (Slow), 10µA (Med), 100µA (Fast)
    10A: 100µA (Slow), 1mA (Med), 10mA (Fast)
    Accuracy ±(0.5% + 5d), Max burden: 200mV
    Overload Protection 0.5A/250V and10A/250V fuse
    Resistance
    Ranges 200W, 2KW, 200KW, 2MW, 10MW
    Best Resolutions 1mW (Slow)
    10mW (Med)
    100mW (Fast)
    Accuracy ±(0.05% + 5d)
    Overload Protection 250V or AC RMS
    Frequency
    Ranges 200Hz, 2KHz, 20KHz, 200KHz
    Best Resolutions 1mHz(Slow)
    10mHz (Med)
    100mHz (Fast)
    Accuracy ±(0.05% + 2d)
    Overload Protection 250V DC or AC RMS
    Diode
    Range 2V
    Test Current Approximately 1.0mA
    Test Volts Approximately 3V
    Continuity Buzzer will sound at 100W or less
    Interface
    Type RS-232
    Connector 9 Pin din
    Baud Rate 1200, 2400, 4800 or 9600 bps
    GPIB optional
    General Specifications
    Display 128 x 64 pixel super twist LCD
    Size 3.3” (H) x 9.5” (W) x 10.5” (D)
    Weight 3.2 lbs
    Operating Temperature 0 to 50°C (32 to 120°F)
    Power 85V to 275V ±10%
    Supplied Accessories Manual, Line cord, Software disk, RS-232 cable, Test Leads
    Optional Acessories GPIB interface