B4004 - 4 1/2 digit 22,000 count Bench Top DMM  
 
 
Click for larger picture

Click on image for larger picture

   
AC line or Battery operated
0.05% DC V Accuracy
Measures Frequency to 220MHz
MIN/MAX, Peak MIN/MAX and Relative modes
Capacitance, and Temperature measurements
Back lit display, Auto power off and Auto/Manual ranging
True RMS AC Volts and Amps measurements
Optically isolated RS232 interface
PC Link software and RS232 to USB cable included
CATII 1000V & CATIII 600V
Can be used with clamp current tranducers Protek 601C or 602C for high current measurements
MSRP: $242.00
 
  •    Related Links
  •    Request Quotation    Request Demo
       Download Product Data Sheet    Download software
     
  •    Specification
  • DC Voltage
    Ranges 200mV, 2V, 20V, 200V and 1000V
    Best Resolution 10µV
    Accuracy ±(0.05% +6d)
    Input Impedance 10MW
    Overload Volts 1000V DC or 750V AC RMS
    AC Voltage
    Ranges 200mV, 2V, 20V, 200V, and 750V
    Best Resolution 10µV
    Accuracy ±(0.5% + 30) 40Hz to 60Hz
    ±(1.0% +30d) 60Hz to 5KHz
    ±(2.0% + 30d) 5KHz to 10KHz
    Input Impedance 10MW
    Overload Volts 1000V DC or 750V AC RMS
    DC Current
    Ranges 200µA, 2000µA, 20µA, 200mA, 10A
    Best Resolution 10nA
    Accuracy ±(0.15% + 15d)
    Overload protection 0.3A /250V and 10A/250V fuse
    AC Current
    Ranges 200µA, 2000µA, 20mA, 200mA, 10A
    Best Resolution 10nA
    Accuracy ±(1.0% + 30d) 60hz to 1KHz;
    ±(1.2% + 30d) 1KHz to 5KHz;
    Overload protection 0.3A /250V and 10A/250V fuse
    Resistance
    Ranges 200W, 2KW, 20KW, 200KW, 2MW, 20MW and 200MW
    Best Resolution 10mW
    Accuracy ±(0.1% + 10d) 200W to 2MW ranges
    ±(0.5% + 10d) 20MW range
    ±(2.0% + 10d) 200MW range
    Logic Frequency
    Ranges 20Hz to 220MHz
    Best Resolution 1mHz
    Accuracy ±(0.06% + 10d)
    Overload Proection 250V
    Linear Frequency
    Input Range/Sensitivity(True RMS) 5Hz to 10KHz (200mV/5mV), (2V/50mV), (20V/500mV), (200V/5V)
    Input Range/Sensitivity(True RMS) 10KHz to 100KHz (200mV/10mV), (2V/100mV), (20V/10V), (200V/10V)
    Temperature
    Ranges -30ºC to 1300ºC (-22ºF to 2372ºF)
    Accuracy ±(1% +2d)
    Duty Cycle
    Ranges 5% to 95%
    Accuracy ±10%
    Capacitance
    Ranges 20nF, 200nF, 2µF, 200µF, 2000µF, 20mF, 200mF
    Best Resolution 10pF
    Accuracy ±(1.2% + 30d) 20nF to 20µF ranges
    ±(2.2% + 30d) 200µF to 20mF ranges
    200mF unspecified
    Overload Protection 250V
    Diode test
    Test Volt 3V
    Test Current 0.6mA
    Overload Protection 250V
    Continuity
    Buzzer will sound at <300W Resistance
    Overload Protection 250V
    Safety IEC61010-1CATII 1000V and CATIII 600V
    General Specifications
    Size 9"(L) x 9.4"(W) x 3.3"(D)
    Weight 3.3 lbs
    Power 9V NEDA battery or 120V AC @ 60Hz
    Accessories Test leads, Operating manual, RS-232 cable to USB cable and PC Link software Temp adapter & thermocouple