| Ranges |
80 mV, 800 mV |
| Best Resolution |
1µV |
| Accuracy |
±0.05% + 10d |
| Input Impedance |
1GW |
|
|
|
|
| Ranges |
8V, 80 V, 800V, 1000V |
| Best Resolution |
100µV |
| Accuracy |
±(0.05% + 10d) |
| Max. Input Voltage |
1000V DC |
| Input Impedance |
10MW |
|
|
|
|
| Ranges |
80mV, 800mV, 8V, 80V, 750V |
| Best Resolution |
1µV |
| AC Volts Accuracy (80mV, 800mV, 8V ranges) |
50/60Hz: ±(0.5% + 10d)) 50Hz - 1KHz: ±(1.0% +10d)) 1KHz - 10KHz: ±(3.0% + 10d)) 10KHz - 20KHz: ±(5.0% + 10d) |
| AC Volts Accuracy (80V and 750V Range) |
1% from 50Hz to 400Hz |
| AC + DC V Accuracy |
±(1.0%+ 10d) 50Hz to 200Hz |
| Max. Input Voltage |
1000 V DC or AC peak |
| Input Impedance |
10MW (1GW 80mV and 800mV) |
|
|
|
|
| Ranges |
80mA, 800mA, 8A, 10A |
| Best Resolution |
1.0µA |
| Accuracy |
±(0.5% + 10d) |
| Overload Protection |
0.8A/250V fuse and 10A/250V fuse |
|
|
|
|
| Ranges |
80mA, 400mA, 8A, 10A |
| Best Resolution |
1.0µA |
| Accuracy |
±(0.5% + 10d) 50Hz to 1KHz |
| Accuracy AC+DC Amps |
±(1.0% + 10d) 50Hz to 200Hz |
| Overload Protection |
800mA/250 fuse and 10A/250V fuse |
|
|
|
|
| Range |
-80dBm to +80dBm |
| Best Resolution |
-0.01dBm |
| Accuracy |
±(1.0% or reading) |
| Default Ref Impedance |
600W (Ref. Impedances from 4W to 1200W maybe selected) |
|
|
|
|
| Ranges |
800W, 8KW, 80KW, 800KW, 8MW, 80MW |
| Best Resolution |
10.0mW |
| Accuracy |
±(0.3% + 10d) |
| Max. Input Voltage |
250V |
|
|
| Diode and Continuity Test |
|
| Range |
8.00V |
| Accuracy |
±(3% + 10d) |
| Buzzer |
Will sound at < 50W |
|
|
|
|
| Ranges |
1KHz, 10KHz, 100KHz, 1000KHz, 8MHz |
| Best Resolution |
0.01Hz |
| Input sensitivity |
0.7V AC rms |
| Accuracy |
±(0.05% + 5d) |
| Max. Input Voltage |
250V |
| Max Frequency read with optional adapter |
1Ghz |
| Secondary Display Reads |
Duty cycle and mS pulse width |
|
|
|
|
| Range |
0 to 99,999 |
| Resolution |
1RPM |
| Accuracy |
±(0.1% + 5d) Note: The RPM function is the secondary display of the frequency measurement and requires the RPM adapter |
|
|
|
|
| Ranges |
1nF, 10nF, 100nF, 1µF, 10µF, 100µF. |
| Best Resolution |
1pF |
| Accuracy |
±(2.5% + 10d), (±5% + 10d), 1nF range |
| Maximum Input Volts |
250V |
|
|
|
|
| Ranges |
-50 to 1372°C (-58 to 2502°F) |
| Thermocouple |
K type |
| Display |
°C primary display °F secondary display |
| Resolution |
0.1° |
| Accuracy |
±(2.5% + 8d) |
|
|
|
|
| Amplitude |
Approx 3V Frequencies from 0.500Hz to 5.000KHz may be selected in 15 Steps |
| Duty Cycle |
Variable from 1% to 99% |
|
|
|
|
| Operating Temperature |
0 to 50ºC (32 to 122ºF) |
| Power |
9Volt battery @ 36 Hours of operation |
| Size |
7.5" (H) x 3.54" (W) x 1.45" (D) |
| Weight |
1.43 lbs |
| Auto Power-Off |
30 minutes or the timer value. |
| Accessories |
Instruction manual, Test leads, Holster, Temperature probe, 9V battery, RS-232 software and cable |
|