| Ranges |
50mV, 500mV |
| Best Resolution |
1µV |
| Accuracy |
±(0.03% + 6d) |
| Input Impedance |
1GW |
|
|
|
|
| Ranges |
5V, 50V, 500V, 1000V |
| Best Resolution |
100µV |
| Accuracy |
±(0.03% + 6d) |
| Max. Input Voltage |
1000V DC |
| Input Impedance |
10MW |
|
|
|
|
| Ranges |
50mV, 500mV |
| Best Resolution |
1µV |
| AC mV Accuracy |
40Hz to 1Khz: ±(0.5% + 40d), 1KHz to 10KHz: ±(1.0% + 40d), 10KHz to 20KHz: ±(2.5% + 40d) |
| Input Impedance |
1GW |
|
|
|
|
| Ranges |
5V, 50V, 500V, 1000V |
| Best Resolution |
100µV |
| AC Volts Accuracy (5V to 500V ranges) |
40Hz to 1KHz: ±(0.5% +40d), 1KHz to 10KHz: ±(1.0% + 40d), 10KHz to 20KHz: ±(2.5% + 40d) |
| Max. Input Voltage |
1000V DC or AC peak |
| Input Impedance |
10MW |
|
|
|
|
| Ranges |
500µA, 5000µA |
| Best Resolution |
10.0nA |
| Accuracy |
±(0.15% + 1d) |
| Overload Protection |
0.5A/250V fuse |
|
|
|
|
| Ranges |
50mA, 500mA |
| Best Resolution |
1.0µA |
| Accuracy |
±(0.15% + 10d) |
| Overload Protection |
0.5A/250V fuse |
|
|
|
|
| Ranges |
5A, 10A |
| Best Resolution |
100µA |
| Accuracy |
±(0.5% + 10d) |
| Overload Protection |
10A/250V fuse |
|
|
|
|
| Ranges |
500µA, 5000µA |
| Best Resolution |
10.0nA |
| Accuracy |
±(0.75% + 10d) 40Hz to 1KHz |
| Overload Protection |
0.5A/250V fuse |
|
|
|
|
| Ranges |
50mA, 500mA |
| Best Resolution |
1.0µA |
| Accuracy |
±(0.75% + 20d) 40Hz to 1KHz |
| Overload Protection |
0.5A/250V fuse |
|
|
|
|
| Ranges |
5A, 10A |
| Best Resolution |
100µA |
| Accuracy |
40Hz to 1KHz 5A: ±(0.75% + 20d) 40Hz to 1KHz 10A: ±(0.75% + 20d) |
| Overload Protection |
10A/250V fuse |
|
|
|
|
| Ranges |
500W, 5KW, 50KW, 500KW, 5MW, 50MW |
| Best Resolution |
10.0mW |
| Accuracy |
±(0.1% + 5d) |
| Max. Input Voltage |
250V |
|
|
|
|
| Buzzer |
Will sound at < 60W |
|
|
|
|
| Ranges |
50nF, 500nF, 5µF, 50µF, 500µF, 5000µF |
| Best Resolution |
10pF |
| Accuracy |
±(1.0% + 5d) |
| Maximum Input Volts |
250V |
|
|
|
|
| Range |
2.5V |
| Resolution |
0.1mV |
| Accuracy |
±(1.0% + 5d) |
| Test Current |
Approx. 0.7mA |
|
|
|
|
| Sensitivity |
+2V to +5V Square wave |
| Accuracy |
±(0.006% + 4d) |
| Frequency Range |
5Hz to 2MHz |
|
|
|
|
| Ranges |
5Hz to 200KHz |
| Best Resolution |
0.001Hz |
| Accuracy |
±(0.006% + 4d) |
| Input Sensitivities (Range/Sensitivity) |
(500mV / 0.1V), (5V / 0.5V), (50V / 4V), (500V / 40V), (1000V / 400V), (5000µA / 1000µA), (500mA / 100mA) |
|
|
|
|
| Range |
0 to 90% |
| Resolution |
0.01% |
| Accuracy |
±10% |
|
|
|
|
| Operating Temperature |
0 to 30ºC (32 to 86ºF) @ relative humidity < 80% 31 to 51ºC (87 to 124ºF) @ relative humidity < 50% |
| Power |
(6) AAA Batteries |
| Size |
7.9" (H) x 3.94" (W) x 1.57" (D) |
| Weight |
1.23 lbs |
| Accessories |
Manual, test leads, RS232 cable and software CD |
|