Home >
Products
>
Multimeters
>
AC/DC Clamp-On
>
6100
|
| 6100 - 3 3/4 digit Auto Ranging DMM with Capacitance, Frequency and Duty cycle
|
| |
| |
|
Click on image for larger
picture
|
|
|
| |
3 3/4 digit, 4,000 count Back lit display |
| |
Appropiate input jacks light up when measurement function is selected |
| |
CAT II 1000V and CAT III 600V input and test leads Safety rating |
| |
Measures Frequency, Duty cycle and Capacitance |
| |
Buzzer and flashing light warning when test leads are connected to the wrong input or overload |
| |
Relative mode and display Hold |
| |
Resettable current overload fuse, no need to open the meter and replace blown fuse |
| |
MSRP: $55.00 |
|
|
| |
|
| Related Links |
|
|
|
| |
|
| Specification |
|
|
|
| Ranges |
400mV, 4.0V, 40V, 400V and 1000V |
| Best resolution: |
100µV |
| Accuracy |
±(0.8% + 2d)1000V range; ±(0.7% + 2d)all other ranges |
| Input Impedance |
10MW |
| Max. input Volts. |
1000V DC or 750V rms |
|
|
|
|
| Ranges |
400mV, 4V, 40V, 400V, 750V |
| Best Resolution |
100µV |
| Accuracy |
±(3.0% + 3d) 400mV range; ±(1.0% + 3d) 1000V range; ±(0.8% + 3d) all other ranges |
| Input Impedance |
10MW |
| Max. input Volts |
1000V DC or 750V rms |
|
|
|
|
| Ranges |
400µA, 4000µA, 40mA, 400mA, 10A |
| Best Resolution |
100pA |
| Accuracy |
±(2.0% + 3d) 10A range; ±(1.0% + 3d) all other ranges |
| Overload Protection |
0.5A/250Volt resettable fuse and a 10A/250Volt fast blow fuse |
|
|
|
|
| Ranges |
400µA, 4000µA, 40mA, 400mA and 10A |
| Best Resolution |
100pA |
| Accuracy |
±(3.% + 5d) 10A range; ±(1.5% + 7d) all other ranges |
| Overload Protection |
0.5A/250V resettable fuse and a 10A/250Volt fast blow fuse |
|
|
|
|
| Ranges |
400O, 4KO, 40KO, 400KO, 4MO, 40MO |
| Best Resolution |
0.1W |
| Accuracy |
±(2.0% + 5d) 40MO range; ±(1.2% + 2d) all other ranges |
| Open circuit voltage |
Approx. 250mV |
| Overload Protection |
250VDC or rms |
|
|
|
|
| Ranges |
4nF, 40nF, 400nF, 4µF, 40µF, 200µF |
| Best Resolution |
1pF |
| Accuracy |
±(5.0% + 5d) 4nF range; ±(3.0% + 5d) all other ranges |
| Overload Protection |
400ma/250V resettable fuse |
|
|
|
|
| Ranges |
9.999Hz, 99.99Hz, 999.9Hz, 9.999KHz, 99.99KHz, 199.9KHz |
| Best Resolution |
0.001Hz |
| Accuracy |
±(3.0% + 5d) all ranges and unspecified greater than 200KHz |
| Overload Protection |
250VDC or rms |
|
|
|
|
| Resolution |
0.1% |
| Accuracy |
±3.0% |
|
|
|
|
| Open Circuit Volts |
0.5V |
| Buzzer will sound |
at less than 50O resistance |
|
|
|
|
| Open Circuit Volts |
1.5VDC |
| Overload Protection |
250VDC or rms |
|
|
|
|
| Base Current |
10µA |
| Open Circuit Vce |
2.8V |
|
|
|
|
| Operating Temperature |
0 to 40º C ( 32º F to 122º F) with less than 70% humidity |
| Dimensions |
7.7" (H) x 3.6" (W) x 2.2" (D) ; 195mm x 92mm x 55mm |
| Weight |
14.3 oz |
| Power |
3 x 1.5V AAA Batteries |
| Accessories |
Test leads, Operator's manual and Batteries |
|
|
|
|
|