| Ranges |
2, 20, 50Volts |
| Best Resolution |
100µV |
| Accuracy |
±(0.05% + 5d) |
| Overload Protection |
100VDC or AC peak |
|
|
|
|
| Ranges |
2mA and 20mA |
| Accuracy |
±(0.05% + 5d) |
| Best Resolution |
0.1µA |
|
|
|
|
| Range |
2V and 20V |
| Accuracy |
±(0.05% + 5d) |
|
|
|
|
| Range |
4 to 20mA (Values from 0 to 24mA maybe obtained through overlapping) |
| Accuracy |
±(0.025% + 5d) |
| Loop Power |
24V |
|
|
|
|
| Type |
2-wire transmitter simulation |
| External Excitation Voltage |
3V min to 50V max |
| Simulation current |
4 to 20mA (Values from 0 to 24mA maybe obtained through overlapping) |
|
|
|
|
| Range |
4mA to 20mA |
| Ramp Times |
5s, 20s, 50s |
|
|
|
|
| Operating Temperature |
-10 to 55ºC (14 to 131ºF) |
| Power |
(1) 9V ANSI/NEDA 1604 battery |
| Size |
7.0" (H) x 3.5"(W) x 1.5" (D) |
| Weight |
10.5 oz |
| Accessories |
Test Leads, Instruction manual, carrying case and 9 Volt battery |
|